GHM中国区代理|martens原厂供应|上海欧臻供 Technical data Power supply Supply voltage : 230 V AC ±10 % 115 V AC ±10 % 24 V DC ±15 % Power consumption : < 5 VA Operating temperature : -10..+55 °C CE – conformity : IEC 61326 05/2004, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11, CISPR16-1/16-2 Input : 0/2..10 V, 0/4..20 mA Ri : current 10 ? voltage 10 k? Accuracy : < 0.1 %, ±1 Digit Transmitter supply : 24 V DC max. 30 mA Fault detection : break of wire (only 4 mA / 2 V) Outputs Alarm outputs : relay SPDT < 250 V AC < 250 VA < 2 A cos φ ≥ 0,3 < 300 V DC < 40 W <2 A Analog output : 0/4..20 mA burden ≤ 500 ?, 0/2..10 V burden > 500 ?, isolated output burden depending Fault indication : break of wire in the measuring circuit → analog output programmable 0 mA, < 3.6 mA or >21.5 mA → alarm relay(s) min. or max. programmable Bus system Modbus : RS485, RTU or ASCII max. 38400 Baud Profibus : Profibus DP Connection : 9pol. D-SUB connector in the front Display : graphic-LCD-Display, 128 x 64 Pixel, with white LCD backlight Case : Polyamide (PA) 6.6 , UL94V-0 acc. to DIN EN 60715, DIN rail TS35 Weight : approx. 450 g Connection : screw terminals 0.14..2.5 mm2 AWG 26..AWG14 Protection class : case IP30, terminals IP20 acc. to BGV A3 电话:021-34140074 传真:021-54971879 邮箱:info@sh-ouzhen.com 公司网站:http://www.sh-ouzhen.com